Chinese Journal of Medical Instrumentation ; (6): 145-152, 2021.
Article in Chinese | WPRIM | ID: wpr-880441

ABSTRACT

Coagulometer, known as blood coagulation analyzer, is a product that can provide accurate test results for medical diagnosis and treatment analysis by detecting a series of items closely related to thrombosis and hemostasis in coagulation reaction. On the basis of previous traditional methods, and with our deep understanding about the principles of hemagglutination detection, we propose a hemagglutination detection method by using the dual-magnetic circuit beads method. Then, the corresponding hemagglutination detection module is designed. The coagulation time of plasma can be measured by detecting the movement of the magnetic beads when the magnetic field intensity is appropriate. The activated partial thromboplastin time(APTT) of plasma is tested when the most suitable magnetic field intensity is found. The results preliminarily show that this blood coagulation test method is valid and the corresponding test module has a potential value in business.


Subject(s)
Blood Coagulation , Blood Coagulation Tests , Magnetic Phenomena , Magnetics , Partial Thromboplastin Time
2.
International Journal of Laboratory Medicine ; (12): 3241-3242,3245, 2016.
Article in Chinese | WPRIM | ID: wpr-686557

ABSTRACT

Objective To explore the procedures of 3Q validation for blood coagulation analyzer under the good laboratory prac‐tice(GLP) system based on the Sysmex CA7000 automatic blood coagulation analyzer .Methods Four test indicators of PT ,APTT , TT and FIB were chosen to conduct the performance verification in the within‐run precision ,between‐day precision ,accuracy ,linear‐ity ,carry‐over contamination rate of the automatic blood coagulation analyzer .They were prothrombin time(PT) ,activated partial thromboplastin time(APTT) ,thrombin time(TT) ,and fibrinogen(FIB) .Results The within‐run precision CV values of PT , APTT ,TT and FIB were 1 .33% ,1 .57% ,1 .47% and 1 .90% ,respectively ;the inter‐day precision CV values of PT ,APTT ,TT and FIB were 1 .73% ,1 .52% ,1 .55% and 2 .14% respectively ;in terms of accuracy ,the normal quality control CV values were 7 .45% ,3 .88% ,-4 .98% and 4 .36% respectively ;the abnormal quality control CV values of PT and APTT were 8 .11% and 8 .77% respectively ;the r value of FIB linear correlation coefficient was 0 .999 3 ,the a value was 1 .02 ;the highest CV value of car‐ry‐over contamination rate was 2 .15% ;the detected results all conformed to the general industry standards and requirements of in‐strument manufacturer .Conclusion The 3Q validation under the GLP system proves that the Sysmex CA7000 automatic blood co‐agulation analyzer is good in performance and is appropriate for the laboratory work of clinical laboratory department .

3.
International Journal of Laboratory Medicine ; (12): 2071-2072, 2014.
Article in Chinese | WPRIM | ID: wpr-455163

ABSTRACT

Objective To adopt the method performance decision chart to evaluate the performance of the Stago R Evolution au-tomatic blood coagulation analyzer .Methods The method performance decision chart was drawn by the results of external quality assessment and internal quality control according to the requirement of the total error in the clinical laboratory improvement amend-ment (CLIA′88) .The 6 indexes of 3 items including prothrombin time(PT) ,activated partial thromboplastin time(APTT) and fi-brin (Fg) were analyzed .Results The 2 indexes of the PT normal level and APTT abnormal level in the automatic blood coagula-tion analyzer were qualified .The PT abnormal level was fine and 3 indexes of the APTT normal level ,Fg normal level and abnormal level were excellent .Conclusion Six indexes of automatic blood coagulation analyzer could be evaluated by the method evaluation decision chart and it was more directly and clearly compared with σvalue statistical table .